Properties:

  • Can be applied on any white primer.
  • After light shuts off, shines in yellow-green bright light.
  • Easy to apply in any means.
  • Good mechanical strength.
  • Limited resistance for outdoor conditions.
  • Have to be coated outdoors with Denrel laquer for UV and climate defense.
  • Super bright light, very smooth coat.
  • Outstanding adherence to the surface.
  • Easy to apply, rapid drying (additional layer may be painted within 1 hour)

Applications:

  • For painting on walls, doors, shelters. Public places like cinema and theater halls, busses, trains, airplanes, etc. all needed warning and guide signs have to be seen in darkness or in emergency situation with no light.
  • Signs and traffic directions at darkness.
  • Lines and direction gaudiness to exits in case of light shut down.
  • Headers and emergency exits.

Technical specifications:

  • Coverage area: 1 liter per 5-6 sqm. (on white primer coat)
  • Recommended thickness: 80-120 mic. dry
  • Recommended number of layers: 2
  • Hardness: >3 Dg (Erichsen)
  • Viscosity: 5-3.5 Pa.sec (Haake)
  • Flexibility: 1 mm (Sheen)
  • Recommended layer thickness: 40-80
  • Density:3-1.45 gm/cm3
  • Resistance to abrasion – 350 cycles (BYK Gardener)
  • UV endurance: 3-6 months, must be coated with uv durable lacquer for exterior use.

Contains:

  • High quality acrylic emulsion.
  • Advanced flexibility and leveling material.
  • Posfluorescent pigments.
  • Special fungicides and preservatives for long term outside conditions.
  • Wetting and leveling materials.
  • Thixotropic substances.

Colors:

  • Yellow-green.

Gloss:

 

Touch-dry time:

  • 2-4 hours.

Drying time period between layer applications:

  • 6 Final: 24 hours.

Implementing method:

  • Brush, spray,

Dilution:

  • Brush/roller: 5-10%
  • Spray: 12-30% water.
  • Airless: 5%-10% Pressure 5-6 atm. nozzle 0.015”

Surface preparations:

  • Clean the surface from all the dirt, dust, grease and shaky or loose paint.
  • Wood: sand well, fill halls with denberschpachtel for wood. Apply a denbercoat primer white.
  • Walls: wash with water in 150 atm. Pressure if dirty, fill all cracks and halls with Denber Schpachtel acrylic for exterior walls and interior with Denberschpachtel. Apply primer white coat of denbertex primer.

Primer:

v     Iron – Denberust white, Epoxyden primer white,

v     Galvanized steel – Tutgum galvanize.

v     Wood – Denbercoat, Compact schpachtel

v     Walls – Denbertex primer

Packaging:

  • 1 liter, 5 liters, 18 liters.

Storage:

  • In a shaded and cool place at room temperature with appropriate ventilation.
  • Keep lids close.
  • The product isn’t resistant to freeze (except the export model)

Shelf life span:

  • 12 months in its original

Equipment cleaning:

  • With water immediately after usage..

 

Quality control:

  • In factory laboratories according to specifications.
  • COA and COC certificate.
  • ISO 9001-2008

Safety precautions:

  • Inedible, keep away from the reach of children.
  • While applying, good air ventilation is important. In case there is not enough air, use ventilation according to the ventilation table.
  • Wear protective glasses, gloves and suits.
  • Avoid direct contact of the paint and/or thinner with the eyes and skin. In case of contact, immediately wash thoroughly with water.
  • In case of an injury immediately get doctors assistance.
  • Read the safety instructions on the labels.
  • See M.S.D.S

Warnings:

  • Don’t mix the product with materials which were not recommended by us.
  • Don’t apply if the temperature is under +7°C.
  • Don’t apply if humidity is over 80%
  • When applying with Airless, do not aim it at anybody a direct hit could be fatal at pressures over 150 atm.
  • Read thoroughly the technical data of the product listed in this section; confirm that everything is understood completely, for clarification contacts our tech. department.
  • All information that is listed in this content is a recommendation merely and cannot be applied in the court of law.
  • The costumer must test & check that this product is compatible with his equipment and needs.
  • The information listed in this section is according to the laboratory conditions (temperature, humidity etc.) which the products were tested.
  • The recommendations listed do not hold any responsibility for this product.
  • Theoretical and actual coverage area are different concepts, the actual coverage is affected by the required thickness of the layers, required number of layers, painting conditions including the amount of paint which spread in the air before touching the surface.
  • The information listed in this section is based on experience and accumulating data, Denber inc., has the right to change the information listed at any time.
  • Paints that have been in stagnation or exposed to air more than needed could have their qualities changed.

Clarifications:

  • Storage room temperature 15°C to 25°C.
  • Over Spray: An effect which occurs in the spraying of paints application. A type of “dust” is created by dry gases of the air, which causing the paint particles to fall dry on the surface (hereafter the “effect”). The impact of this “effect” becomes stronger due to over pressure and heat, (most sprayers have a lever to control the pressure) To avoid the negative impact 0f the “effect”, the pressure of the spraying should be lowered to the necessary minimum!. Another possibility is to increase the amount of the thinner in the mixture which would cause the paint particles to fall wetter on the surface.

An additional recommended possibility, to avoid this “effect”, is to add a retarder to the mixture which increases the duration period of the painting application , avoiding the paint to  dry up, and enabling it to reach the surface wetter, Thus a better painted smooth  layer is formed.

  • Pot Life: The working time which is possible to paint a mixture of two components, A+B (or more) without spoiling the qualities of the paint or disqualifying the paint as “out of use”.
  • Spray: It is possible to spray with a sprayer that has a container holding the paint that sprays it with air pressure.
  • Airless: a device with a piston which compresses the air for spraying paints. The pressure might be high (over 100atm.) Don’t aim it at anyone
  • Surface preparations: the level of cleanness is determined by international standards. Surface preparations, including cleansing sand blasting, is important & critical factor in achieving an optimal result for painting adhesion on a certain surface. These standards are equally compared to the standards of the Swiss SA, the German-Din the U.S SSPC SP For each standard in any level there are indicators, for sale, in order to make visual comparison between the cleansing of the surface and the indicator.

Quality inspection:

  • Prior to the painting on large surfaces it is important to test the product on a small area, to be sure that the paint is compatible with the level of satisfactory.
  • Laboratory testing was made according to the standards institution specifications.
  • This “Data sheet” given as noncommittal information, the product above recommended for professional painting specialists. This information is not a substitute to personal guidance.
  • You must read the MSDS safety instructions before you start working with the product.