Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Advanced technology development of bi component primer epoxy flame retardant for steel coating antiflame fire protection systems as primer, anticorrosive and rust converter together in one product, high build, solids rich, can apply on light rusty metals without the need for perfect sand blasting, for metal profiles where perfect rust remover is not able to be done.
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Anti corrosive primer rich with zinc phosphate and rust converter elements, extremely strong with particularly unique molecular structure. Produced for requirements of partial preparing surface with easy rust residue. Provides a base strong paint layer with a high adhesion to iron metals that is also used as the basis before coating “Denbercryl Antiflame” against fire and top coat “Tutgum Antiflame” or “Denbergloss Antiflame”
Tested in Israel institute of standards – standard 755 and 931
Properties:
- Flame retardant primer paint with high mechanical strength and high metal adhesion for iron rusty metals
- Creates a worthy preparation for painting with Denbercryl Antiflanme” on it.
- Anti corrosive and rust converter protects from oxidization and rust.
- Durable in high moisture environment conditions and in alkali and acid liquids.
- Offering a superior adhesion to iron rusty metals. Also used as bridge layer on old paints before painting the layer on top.
- Easy to apply, quickly drying.
- Ready to repaint/re-coating again on the same day or after 12 hours.
- High coverage.
- Durable in fuels including aviation fuel.
Applications:
- As primer in fire protection paint systems for steel protection.
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Technical data:
- Coverage – 1 liter to 16 sqm. in a layer of 50 microns.
- Hiding power – a layer of 58 microns > 0.95
- Flexibility – 1 mm (sheen)
- Density –part A =1.35-1.45 gm\cm3 part B =0.85-0.95 gm\cm3(ASTM D1475)
- Viscosity part A + part B immediately after mixing – 40 seconds # 4
- Hardness – >10 Dg (Erickson)
- Flash point – 38oC
- Solids – part A 68% by weight, part B 52% by volume(ASTM-D-2369)
- Erosion-120 microns film – 1560 cycles (Gardner) ASTM
- Recommended layer thickness – 15-23 microns dry (minimum values)
- Recommended number of layers – at least 2
- Touch-drying time Up to 5 hours.
- Hard drying time – up to 8 hours.
- Pot life (working time from mixing a with b) – 4 hours. (After 4 hours blend B + A viscosity less than 70 seconds on cup 4 # after 8 hours will not show jell)
- Mixing ratio A: B – 2.5 : 1 by volume.
- Waiting time after mixture and before painting: 10 minutes. And stir again with a mechanical mixer before start painting.
- Heat resistance- for 1 hr. in 121oC without changes of shade or quality of the film.
- Hot oil durability – 121oC for 24 hours without any changes in the quality of the film and the shade.
- Oil hydraulic resistance point- 65oC for 24 hours without any changes in the quality of film and it shade.
- Solvents durability – 50 cycle rubbing with cloth soaked in MEK – no peeling of paint.
- Distilled water resistance – 4 days in 49oC – no defects of film and adhesion.
- Adhesion test – stick 3M standard tape to surface under pressure of 2 kg and after 1 hr. pull it off – no paint split off the surface.
- Paint removing – 90% and more within 60 minutes in paint remover.
- Salt spray resistance – 2000 hr.
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Contains:
- Epoxy resin flame retardant and polyamide hardener according the MIL-SPEC.
- Fillers, anticorrosive pigments.
- Rust converters components.
- Polyamide hardeners.
- Zinc phosphate.
- Solvents and additives
Colors:
- Red/Brown, Grey
Gloss:
- Matt < 5% (ASTM D 523) 60o lens test
Touch dry time:
- : 12 minutes to 5 hours. (Due to the quick drying time avoid from over spray, avoid spraying “dust”)
Drying between layers:
- 6-8 hours. Final drying: 8 hours.
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Application methods:
- Brush, roller, spray.
- Spray gun – it is recommended inter pressure > 4 atm.
- Airless – dilution 0-5% nozzle 0.021 “
Thinning:
- Thinner D-4/100. (MIL-T-81771 Type II)
- 10-25% by volume -according to need. if orange peel appearance you can increase the dosage to 35%
- Spraying with spry gun – 10-25%
- Airless – 0-5%
Surface preparation:
- A thorough cleaning needed from dirt, dust and loose paints.
- On old paint – sand well and clean with air pressure, clean with dry clean cloth soaked with thinner.
- Iron Metals – recommended but not must – sand blast cleaning till white metal.
- Very big surfaces –remove the paint with paint removers and wash with water for neutralizing. Sand/spray soft sands or plastic powder for light roughness. Rinse with water and dry completely.
Primer:
- This product itself.
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Mid. layer:
- Denbercryl antiflame 8-12 hr. after the primer applying. In winter 24 hr. after applying the primer coat.
Top layer:
- Denbergloss antiflame for UV protection and decoration. Also for durability in harsh extreme conditions like sea environment. Or Tutgum Antiflame for usual city conditions.
Instructions for use:
- Open carefully parts A and B and stir separately.
- Pour from two parts in the right ratio the required amount and mix well with mechanical mixer (operated by air pressure is recommended for safety reasons) for a uniform mixture.
- Wait for 10 minutes while adding the thinner as needed and mix again. Spray a thin layer of at least 23 microns thickness dry film. If necessary if the layer does not completely uniform or part of surface not painted, wait about 4-12 hours for complete drying and spray another layer. Insert into clean and controlled temp. drying room for 12 hours before painting the top layer.
- Wash the equipment well immediately after finishing painting.
Pot Life after mixing the mixture a + b of 5 liters:
- 15oc – 10 hr.
- 20oc – 8 hr.
- 25oc – 6 hr.
- 30oc – 5 hr.
- 35oc – 4 hr.
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Ventilation:
- Quantity air needed for 1 liter of blend paint :
- Achieving 10% of the LEL = 65M3
- To obtain the TLV = 990 M3
Packaging:
- 4 + 1 = 5 liters.
Storage:
- In cool and shaded room in room temp. with proper ventilation.
- Keep lids tightly closed.
Shelf life:
- 12 months in original package.
Tools cleaning:
- D- 4/100 thinner immediately after painting.
Quality control:
- In factory laboratories according to specifications.
- COA and COC certificate.
- ISO 9001-2015
Epoxyden Primer AF Anti flame Antirust Rust Converter
STANDARD 755 + 931
Visit our sites: www.denber-paints.co.il
- www.denber-colors.co.il
- Varnish for wood. How to choose the right varnish for wood
- Thermal isolation Thermoseal 200 energy saving in green construction
- Crystal epoxy resin for tables
- Fire resistance of houses, hardwood and parquet floors, decks
- Sealing the floor of the balcony, terrace from rain
- Thin floor nano-coverings for industrial refrigerators and freezers
- Epoxy floors – Benefits of epoxy floors
- Swelling paints for steel protection against fire – Fire retardant paint
- As part of the restoration of buildings – concrete restoration at the Yad Kennedy site
- Paint for aircraft Denbergloss Jets
- Complicated sealing based on innovative technologies
- Reconstruction project of a unique house (Israeli house of architect Gaudi); Renovation of condominiums
- The work on the floor covering and restoration of the sports hall has been completed
- Denber has developed an innovative solution for thermal insulation works
- Mold, how to remove mold correctly and how to fight mold
- “Sick” buildings – Antibacterial paints destroys viruses / bacteria – Bacterinoll/ Tutgum Bacterinol
- Denber – floor coating using epoxy and polyurethane – find out what is suitable for you epoxy floor or polyurethane floor
- Epoxy floor coating and epoxy paints