Epoxyden HB AF Anti-flame 755 + 931

Epoxyden HB AF Anti-flame 755 + 931

Fire retardant protection thick coat for casting 82% solids

Special thick coat to prevent fire expansion in case of fire, transparent and tinted decorative thick layer to use for powerful coating on printed circuits in electronics, for protecting concrete and parquet floors, thick coat for protecting metals, for coating  composed materials against fire.

* Tested by the standards institution of Israel-standard 755

Epoxyden HB AF Anti-flame 755 + 931. www.denber-paints.co.il

Epoxyden HB AF Anti-flame 755 + 931. www.denber-paints.co.il

Properties:

  • Fire protection coat.
  • High pressure and scratches resistance.
  • Good adhesion to metal, concrete, wood and any dry and not smooth infrastructure.
  • Contents 18% soft solvents.
  • 82% solids.
  • Appropriate for using on printed circuits.
  • Appropriate for coating floors in industry.
  • Can be applied in one thick layer
  • In red brown/grey/black/ocher colors it is also rust resistance.
  • Tree elements: in Varnish transparent tints or clear for wooden floors and wooden objects and in many colors according catalog.
  • Can be implemented in thin layers.
  • Prevent fire expansion.
  • Resistant to salt and dry environment.
  • Washable and repulsive dust & dirt.

Applications:

  • For painting iron metals to defend from melting in fire.
  • Wooden objects, roofs, walls and floors to prevent fire.
  • Electric transformations to prevent fire and vibrations.
  • Protection from fire spreading on printed circuits in the electronic industry.
  • For immediate treatment in places being used for works with life fire or welding executed.

Technical Data:

  • Theoretical spreading rate: 1 liter per 15 m 2·
  • Theoretical field: 6-7 m 2/liter for 150 mic.
  • Recommended layer thickness: Minimum 150 micron, maximum 1 cm.
  • Recommended number of layers: as much needed to coat or fill.
  • Density: 0.9-1.35 gm/cm 3··
  • Hardness: >3 Dg (Erichsen).
  • Elasticity: 4 mm (Sheen).
  • Viscosity: 2-4 Pa.sec (Haake).
  • Mixing rate a:b by volume: 1:1.33

Contains:

  • Special Epoxy resins rich with Flame retardants.
  • Flexibility materials.
  • High temperature resistant fillers.
  • Additives.
  • Solvents.
  • Hardeners.

Colors:

  • Transparent, black, red oxide, brown, dark green, dark yellow, gray and more …

Gloss:

  • Silk.

Touch-drying time:

  • 60 minutes to a layer of 150 micron.

Repainting Gap Time:

  • 12 hours,  final- 36 (to a layer of 150 micron. for thick layers up to 3 days, and up to 7 days for layers of 4cm and more thickness).

Recommended Application Methods:

  • Cast, brush.

Dilution:

  • No dilution.

Surface Preparation:

Metal:

  • Mechanical or chemical cleaning until a white metal appears.
  • Mechanical: steel brushes st-3 or sand blast SA-2.5
  • Chemical: rust -“rust remover 3000”, grease -“Degreazer M”.
  • Primer coat with Epoxyden primer antiflame.

Concrete:

  • Sand blast cleaning and vacuum.
  • Or acid burn and water high pressure cleaning.
  • Or polishing with diamond stones and vacuum.
  • Primer with Epoxyden floor primer antiflame.

Wood:

  • Sand well and clean.
  • Primer – Isolation primer antiflame.

Printed circuits:

  • Cleaning the surface with air pressure and pure isopropyl alcohol.

Kit Description:

  • 0.75 liter, part A + 1 liter part B
  • 1.9 liter, part A + 2.5 liter part B
  • 3.8 liter, part A + 5 liter part B
  • 15 liter, part A + 18 liter part B

Storage:

  • Appropriate shaded room temp. with proper ventilation.
  • Keep lids tightly closed.

Shelf Life:

  • 12 months in original sealed package.

Tools cleaning:

  • Clean with thinner D-4/100 immediately after complete painting.

Quality control:

  • In factory laboratories according to specifications.
  • COA and COC certificate.
  • ISO 9001-2015

Epoxyden HB AF Anti-flame 755 + 931

Safety precautions:

  • Inedible, keep away from the reach of children.
  • Flammable – keep distant from heated areas, fires, flames, and sparks, Prohibit smoking in working area.
  • While applying, good air ventilation is important. In case there is not enough air, use ventilation according to the ventilation table.
  • Wear protective glasses, gloves and suits.
  • Avoid direct contact of the paint and/or thinner with the eyes and skin. In case of contact, immediately wash thoroughly with water.
  • In case of an injury immediately get doctors assistance.
  • Read the safety instructions on the labels.
  • See M.S.D.S

Warnings:

  • Don’t mix the product with materials which were not recommended by us.
  • Don’t apply if the temperature is under +7°C.
  • Don’t apply if humidity is over 80%
  • When applying with Airless, do not aim it at anybody a direct hit could be fatal at pressures over 150 atm.
  • Read thoroughly the technical data of the product listed in this section; confirm that everything is understood completely, for clarification contacts our tech. department.
  • All information that is listed in this content is a recommendation merely and cannot be applied in the court of law.
  • The costumer must test & check that this product is compatible with his equipment and needs.
  • The information listed in this section is according to the laboratory conditions (temperature, humidity etc.) which the products were tested.
  • The recommendations listed do not hold any responsibility for this product.
  • Theoretical and actual coverage area are different concepts, the actual coverage is affected by the required thickness of the layers, required number of layers, painting conditions including the amount of paint which spread in the air before touching the surface.
  • The information listed in this section is based on experience and accumulating data, Denber inc., has the right to change the information listed at any time.
  • Paints that have been in stagnation or exposed to air more than needed could have their qualities changed.

Clarifications:

  • Storage room temperature 15°C to 25°C.
  • Over Spray: An effect which occurs in the spraying of paints application. A type of “dust” is created by dry gases  of the air, which causing the paint particles to fall dry on the surface (hereafter the “effect”). The impact of this “effect” becomes stronger due to over pressure and heat, (most sprayers have a lever to control the   pressure) To avoid the negative impact 0f the “effect”, the pressure of the spraying should be lowered to the necessary minimum!. Another possibility is to increase the amount of the thinner in the mixture which would cause the paint particles to fall wetter on the surface.

An additional recommended possibility, to avoid this “effect”, is to add a retarder to the mixture which increases the duration period of the painting application , avoiding the paint to  dry up, and enabling it to reach the surface wetter, Thus a better painted smooth  layer is formed.

  • Pot Life: The working time which is possible to paint a mixture of two components, A+B (or more) without spoiling the qualities of the paint or disqualifying the paint as “out of use”.
  • Spray: It is possible to spray with a sprayer that has a container holding the paint that sprays it with air pressure.
  • Airless: a device with a piston which compresses the air for spraying paints. The pressure might be high (over 100atm.) Don’t aim it at anyone
  • Surface preparations: the level of cleanness is determined by international standards. Surface preparations, including cleansing sand blasting, is important & critical factor in achieving an optimal result for painting adhesion on a certain surface. These standards are equally compared to the standards of the Swiss SA, the German-Din the U.S SSPC SP For each standard in any level there are indicators, for sale, in order to make visual comparison between the cleansing of the surface and the indicator.

Quality inspection:

  • Prior to the painting on large surfaces it is important to test the product on a small area, to be sure that the paint is compatible with the level of satisfactory.
  • Laboratory testing was made according to the standards institution specifications.
  • This “Data sheet” given as noncommittal information, the product above recommended for professional painting specialists. This information is not a substitute to personal guidance.
  • You must read the MSDS safety instructions before you start working with the product.

Epoxyden HB AF Anti-flame 755 + 931

Epoxyden HB AF Anti-flame 755 + 931